The relief valve and the relief flame arrester valve is suitable for the storage tank of organic solvent, which can only breather out the gas, can`t breather in the gas from outside, which will make sure the outside air can`t get in touch with the inner side medium.

The relief valve and the relief flame arrester valve is suitable for the storage tank of organic solvent, which can only breather out the gas, can`t breather in the gas from outside, which will make sure the outside air can`t get in touch with the inner side medium. The relief valve can take the exhaled pipe and recover the exhaled gas. The valve can not only maintain the air pressure balance of the tank, ensure the damage of the tank in case of over pressure or vacuum, but also reduce the medium and loss in the tank. The working principle of the relief ( flame arrester ) valve is to use the spring to control the valve plate, which is determined by the setting pressure and VOC pressure, to make sure the valves breather in or breather out.

 

 

Operation Pressure for the Relief ( flame arrester ) Valve:

 

 

A Type:-295Pa(-30mmH20) +355Pa(+36mmH20)
B Type:-295Pa(-30mmH20) +980Pa(+100mm H20)
C Type:-295Pa(-30mmH20) +1750Pa(+180mm H20)

D Type:-295Pa(-30mmH20) +9800Pa(+1000mm H20)

 

 

Maintenance methods

 

 

1. Storage: after the above products are transported to the construction site, if they are not installed at that time, all the valves shall be stored in the warehouse with rainproof facilities; the relief ( flame arrester ) valves shall not be inverted during transportation.

2. Maintenance:

a. The relief ( flame arrester ) valves should be inspected every month, checking whether there is dust, dirt on the valve disc, valve seat, valve stem, valve sleeve and other parts. If there is any, it shall be cleaned up; every half a year, wipe the transformer oil on the valve sleeve and valve rod.

b. Check the flame arresting tray of the relief flame arrester valve every half a year. If any stain or impurity is found to block the flame arrester tray, take out the trims, remove the stain with the corresponding solvent, clean the trims with clean water, then make it dry, put it in the shell after ventilation and drying.

c. The paint on the inner and outer surfaces of the relief ( flame arrestor ) valves be repainted once a year.

 

 

Specification

 

 

product-1012-358

 

Relief Valve Relief Flame Arrester Valve Relief Flame Arrester Valve with Suction Nozzle

Model

PHXF-V

Explosion Group

BS 5501: IIA IIB IIC

Size

DN50-350 GB81-59 PN0.6-2.5 FF,RF

Temperature

CS : -30℃ ~ + 350℃ SS : -80℃ ~ + 480℃

Body Material

L2 A3 304 304L 316 316L

Flanges

HG GB SH HGJ JB ANSI JIS

Trim Material

304 304L 316 316L

Positive Disc Material

L2 A3 PTFE 304 304L 316 316L

Bolt/Nut

20# 304 304L 316 316L

Set Pressure

+ 36mmH2O -- + 1500mmH2O

Diaphragm (P/V)

NBR PTFE Metal Gasket

Manufacture Inspection

GB5908-86 SY7511-87

Jonit Type

Flange / Threaded

Coating

CS : Paint SS : natural color

DN

25

50

80

100

150

200

250

300

Inch

1

2

3

4

6

8

10

12

Length

160

290

420

420

535

700

835

950

Height

255

320

470

470

540

620

700

780