Products
Breather Valve With Flame Arrester
video
Breather Valve With Flame Arrester

Breather Valve With Flame Arrester

Chongqing Hongar is an ATEX-certified Breather Valve with Flame Arrester designer and manufacturer with extensive experience, providing advanced safety equipments over 15 years.
, Breather Valve with Flame Arrester is a device of combine which allows gas & solvent to pass through it but stops a flame in order to prevent with safe of tank for pressure & vacuum & save your material of continue losses and safe with larger fire or explosion.
, Breather Valve with Flame Arrester is a tank protection device that protects tanks and vessels against overpressurization and fire. This is a Breather Valve with Flame Arrester.
, These are often of the dead weight variety for pressures that are set to standards. These can be provided with a spring load if higher set pressures are needed. With the use of an arrestor element, the Flame Arrestor is intended to control the propagation of flame within a container. By absorbing and diffusing the flame's heat below the flash point, the element puts out flames. The arrestor releases the vapour and lowers the temperature of an incoming flame to below the vapor's ignition point, shielding the exposed side of the device.

Breather Valve with Flame Arrester

Breather Valve with Flame Arrester provides protection to bulk storage tanks and vessels from over and under pressurization. The valves can be mounted on the tank roof flange or a vent pipe from the vapour space. In the closed position the pressure relief pallet and diaphragm assembly are held tightly against a seal to prevent the loss of vapour to the atmosphere. As the internal pressure in the tank increases, due to product filling and vapour accumulation, the pressure in tank increases and in the event that the set pressure of the valve is reached, the diaphragm will open and discharge the gas into the atmosphere. The opening set-point is selectable from a range between +2.0 mbar and +60 mbar. The valve will close when the tank returns to a safe pressure.
The vacuum pallet and diaphragm assembly is also maintained in the closed position. As the internal pressure in the tank reduces, due to emptying, the balance between the tank pressure and the external atmospheric pressure changes, and when the set pressure of the unit is reached, the diaphragm opens to admit air and rebalance the internal pressure. The vacuum set-point is selectable from a range between +2.0 mbar and +60 mbar. The valve will close again when the tank returns to a safe pressure.
Several features are inherent in the valve design to ensure a smooth, positive and effective operation. The body is self-draining and drip rings prevent condensate from settling on seating surfaces. A diaphragm and seal manufactured from Teflon reduce the possibility of ice formation and sticky residues hindering the valve from opening, while the pallet assembly moves freely on guide posts.
The Breather Valve with Flame Arrester is an advanced design for vent to atmosphere applications. Designed manufactured and tested according to the API 2000 code,BS7244, and EN12874 these valves utilize the latest technologies to provide protection against positive or vacuum over pressure and prevent air intake, evaporative losses of product and help to contain odorous and potentially explosive vapours.


 

Products Description

 

 

Name:Breather Valve with Flame Arrester
Pressure Setting: 20mmW.C to 10000mmW.C
Vacuum Setting: 20mmW.C to 10000mmW.C
Body Material: WCB / CF8 / CF8M / Cast Aluminum
End Connection: FF / RF Flanged End
Size: 1" - 12"

The Unit Will Comprise:
In-line Deflagration Flame Arrestor (flanged)
Breather Valve with Flame Arrester (weight-loaded; discharge to atmosphere)

Operating pressure:
Type A: +355pa(+36mmH2O) -295pa(-30mmH2O)
Type B: +980pa(+100mmH2O)-295pa(-30mmH2O)
Type C: +1950pa(+200mmH2O) -295pa(-30mmH2O)
Type D: according to user requirement (special pressure rating)
Material:WCB SS304 SS304L SS316 SS316L
Flange Standard: HG/T20592-2009 ANSI B16.5
HG/T 20615-2009(Class series)
HG/T20592-2009 (PN series)
ANSI B16.5
AMSE B16.5
Note:
Under normal circumstances, (fire) breathing valve operating pressure to B shall prevail;
Applicable materials: gasoline, kerosene, diesel, aromatics, sulfur, air and other petrochemical materials;
Environment temperature: -40 °C -+60 °C;
Shell material: HT, AL, A3, 18-8, 304, 304L, 316, 316L.
Flange standards: HG20592-97 PN1.0 (also can be produced according to user specified criteria)

 

 

Products Display

 

 

88

 

 

Product Application

 

Breather Valve with Flame Arrester is essential safety equipment used in multiple industries to protect vessels, tanks, and personnel from the risks of overpressure, vacuum, and flame spread. These pressure vacuum vent valves are designed to prevent hazardous pressure or vacuum buildup inside tanks, vessels, or pipelines due to temperature, liquid level fluctuations, or external events such as fires or explosions.

99

 

 

product certificate

 

 

Chongqing Hongar Industries Equipment Co., Ltd. is a wholly-owned subsidiary of Chongqing Jeri Marine Equipment Co., Ltd., specializing in the production of pipeline equipment such as valves, pumps, and fittings.

We supply and service a wide range of detonation and deflagration flame arresters to prevent the onward travel of a flame path and keep facilities safe.
All our Breather Valve with Flame Arrester is:

Compliant with ISO 16852:2008.
ATEX rated.
Manufactured to ISO9001.
Easy to service.
Cost effective.
Supplied with a document pack which includes certified drawings, test certs, welding specs, material test certs;

ISO9001

Hot Tags: breather valve with flame arrester, China breather valve with flame arrester manufacturers, suppliers, factory, Automatic Vacuum Relief Valve, Gas Tank Breather Valve, Nozzle Breather Valve, Pressure Vacuum Breather Valve, Relief Breather Valve, Steel Breather Valve

Send Inquiry